Rossmax Digital Thermometer Tg100 provides quick, highly accurate reading over the human body temperature range. Please read the instructions completely first.

How to Use

1.Push the On/Off button by the display window. The display will
read

beep sound will be heard

for 2 seconds and beep sound will be heard.

2. Releasing the on/off button, last measured temperature will be shown for about 2 seconds. Then shows the self-test temperature 37.0°C(98.6°F),and then Lo°C (Lo°F) displays.

3. Wipe or dip the probe with alcohol for disinfection. Position the probe in oral, rectal or axillary site.

4. Once the degree sign °C ( °F) on the display has stopped flashing (usually within 30 to 60 seconds), an Beep signal will sound for approx. 10 times, the measured temperature is shown on LCD window. The temperature reading will not change after the unit is removed from testing position. If the temperature <37.8°C(100.0°F ), the buzzer will alarm “Bi—Bi—Bi—Bi—”. If the temperature ≥ 37.8°C (100.0°F), the buzzer whose frequency is higher will alarm “Bi-Bi-Bi—-Bi-Bi-Bi–” about 10 times rather than”Bi—Bi—Bi—Bi—”

5. The unit will automatically turn off in 10 minutes for energy saving. However, to prolong the life of the battery, it is suggested to press the On/Off button to turn the unit off once the measurement is done.

6. Please dispose of any used battery and the thermometer according to the local regulations.

Note: After step 2, if the room temperature is greater than 32.0°C (89.6°F ). it will be displayed the room temperature. Note: Usage of the probe cover may result in a 0.1°C(0.2°F) difference from actual temperature.

Note: To clean the probe before and after using the thermometer to ensure an accurate reading and avoid cross contamination approximately.

Oral Use

Place the probe well under the patient’s tongue. Confirm the patient to keep his mouth closing for about 1 minute.

Do not drink hot or cold fluids, exercise, and smoke or perform other activities prior to a reading. These activities will raise or lower temperature readings when compared to your normal, average temperature.

Axillary Use

Tightly place probe in the patient’s armpit for about 1~5 minutes. *Please ensure the close contact between the probe and the armpit of the baby or children.

Rectal Use

Always uses probe cover when taking rectal measurements.

  1. Commonly used for young children when it is difficult to take an oral or axillary temperature.
  2. Lubricate with a water-soluble gel. Do not use petroleum jelly.
  3. Gently insert the probe tip no more than 1.5-2 cm into the rectum
    for about 1 minute. Do not force the tip into the rectum if resistance is encountered.
  4. Disinfect the thermometer after use. Refer to “cleaning and disinfection“section.

ºC /ºF Switchable

Temperature readings are available in the Fahrenheit or Celsius scale (°C / °F; located in the right of LCD.) With the unit off, press and hold the On/Off Button for approximately 4 seconds to change the current setting.

Weight 0.2 kg
Dimensions 17 × 2.3 × 21 cm
Rossmax Digital Thermometer Tg100 Rossmax Digital Thermometer Tg...